Table of Contents
JAMB CBT CENTER ACCREDITATION REQUIREMENT
A. Network Cable for Biometric Verification
✓ A single NETWORK CABLE to connect biometric verification system (point) to Server Room
✓ All biometric verifications (before & after examination) would now be captured real-time by JAMB Examination Delivery Server
✓ No show should have his/her biometrics & picture freshly captured at the Centre
✓ Use of STAR TOPOLOGY for LAN for easy troubleshooting and system maintenance
*RECOMMEND EXAMINATION SESSION PER DAY
✓ Every CBT Centre must have capacity to hold 4 examination sessions per day
✓ The fourth session would be used as reserve session provided for rescue services
*SUBSISTING ACCREDITATION REQUIREMENT*
✓ All CCTV Systems must be wired. No more wireless CCTV Systems
✓ CCTV cameras must cover all areas about examination:
verification area
Holding room
work ways (if any)
examination hall,
Server room
Entrance & exit doors
✓ Holding Rooms must be in good proximity to the examination hall & must be adequately sized
✓ Make-shift CBT centres are NOT allowed; all centres must therefore be dedicated CBT centres that are used and maintained as such all year round
✓ 100 Access codes to each Centre & monitored
✓ Opening of a minimum 10 access point out 100 for each Centre
✓ All centres must be within MTN or AIRTEL network coverage
✓ All Centre networks must be powered by Switches. No hubs allowed
✓ Centres are strongly advised to use static IP addresses rather than Dynamic IP Addressing
✓ Conveniences both within the Examination hall and waiting areas
✓ Their must be no flying cables. All cables MUST be trunked
JAMB CBT CENTER REGISTRATION REQUIREMENTS
A. Mapping of NIMC Enrolment Centres
✓ NIMC enrolment centres mapped with CBT Centres to attend to candidates who may come for UTME/DE registration but do not yet have National Identification Number (NIN)
✓ JAMB would provide transportation to such candidates to and fro the mapped NIMC enrolment centre at no cost to the candidates
✓ 20 access codes to each Centre & monitored
✓ Opening of a minimum 10 access point out 20 for each Centre
✓ No more scanning of Picture. All pictures will be captured live through USB cameras
✓ All registration points must have dual screens each facing the operator and candidate. Candidates must be able to review their data before submission
✓ Candidate must preview registration before submission
✓ Every Centre must open NOT less than 10 registration points
✓ All registrations require biometric fingerprint authentication to print first copy of registration slip
✓ Use Futronics FS80H Fingerprint Scanner
✓ LED table top lights must be provided for bright picture